| 1200W AC/DC POWER SUPPLY (1...3 OUTPUT/S) |
|
|
|
| GENERAL FEATURES: |
•Active PFC
•Adjustable output voltage.
•Separate enable for each output (O1/O2/O3).
•Led for each output presence.
•AC failure detection.
•Reduced size (planar tech. use).
•Auxiliary output (5V/0,35A). |
|
|
STANDARD MODELS CHART
| Model |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
| KDX-1200-8287 |
24Vdc 15A |
24Vdc 15A |
24Vdc 15A |
5Vdc 0,35A |
| KDX-1200-8287/U |
24Vdc 45A |
- |
- |
5Vdc 0,35A |
| KDX-1200-8287/S1 |
24Vdc 30A |
|
24Vdc 15A |
5Vdc 0,35A |
| KDX-1200-8287/S2 |
24Vdc 15A |
24Vdc 30A |
- |
5Vdc 0,35A |
| KDX-1200-8289 |
48Vdc 7,5A |
48Vdc 7,5A |
48Vdc 7,5A |
5Vdc 0,35A |
| KDX-1200-8289/U |
48Vdc 22,5A |
|
|
5Vdc 0,35A |
| KDX-1200-8289/S1 |
+48Vdc 15A |
|
-48Vdc 7,5A |
5Vdc 0,35A |
| KDX-1200-8289/S2 |
+48Vdc 7,5A |
-48Vdc 15A |
|
5Vdc 0,35A |
|
Other options can be delivered under request:
| 24V+24V+48V |
24V+48V+48V |
12V+24V+24V |
48V 15A + 24V 15A |
72V 15A |
|
TECHNICAL SPECIFICATIONS :
| Mains voltage: |
154...264Vac |
| Mains frequency range: |
47...63Hz |
| DC input voltage: |
217...375Vdc |
| Power factor: |
>0,96 (active PFC) |
| Inrush current: |
<40A (Vin=230Vac) |
| Efficiency: |
>88% (typical) |
|
| |
Out1/Out2/Out3
(each output)
|
Out1/Out2/Out3
(each output)
|
Auxiliary |
| Output voltage: |
24Vdc |
48Vdc |
5Vdc |
| Voltage adjust range: |
23...28Vdc |
46...56Vdc |
-- |
| Maximum continuous current (Io): |
15A |
7,5A |
0,35A |
| Load regulation: |
<0,2% |
<0,2% |
<100mV |
| Temperature regulation: |
<0,007%/ºC |
<0,007%/ºC |
<0,8mV/ºC |
| Ripple: |
<50mVpp |
<100mVpp |
<30mVpp |
| Noise (BW 20MHz): |
<200mVpp |
<200mVpp |
<100mVpp |
| Hold-up time: |
>10ms |
>10ms |
>20ms |
| Total output power (Po): |
1200W |
|
| Storage temperature: |
-40...85ºC |
| Operating temperature range: |
-25...50ºC |
| Cooling: |
Controled forced air |
| M.T.B.F.: |
≥150.000h |
| Immunity according to norm/s: |
EN61000-6-2 |
| Emission according to norm/s: |
EN61000-6-4 |
| Harmonic current emissions: |
EN61000-3-2 Class A |
| Safety according to norm/s: |
EN60950 Class I |
| Dielectric strength In-Out/ In-Gnd/ Out-Out/ Out-Gnd: |
3000Vac /1500Vac /500Vac /500Vac |
| Dimensions: |
≤45x153x306mm |
| Weight: |
≤2,5Kg |
|
PROTECTIONS
•Against overloads and shortcircuits.
•Overtemperature protection shutdown.
•Separate Enable for O1/O2/O3.
•General shutdown.
•AC power OK (open collector).
•Output O1/O2/O3 presence led.
|
| |
 |
Puede
obtener más información del producto (diagrama de bloques, conexionado, etc.. ),
descargando