| 100W
AC/DC POWER SUPPLY (SINGLE OUTPUT) |
|
|
|
| GENERAL FEATURES: |
Built-in RFI mains filter.
Selectable input line voltage.
Adjustable output voltage.
No minimum load required.
Floating output voltage.
Power on indicator (led).
Standard size Eurocard 3U. |
|
|
STANDARD
MODELS CHART
| Model |
V out |
I out |
Max.
power |
Typical
efficiency |
| 8061 |
5V |
13,0A |
65W |
74% |
| 8063 |
12V |
6,3A |
75W |
76% |
| 8065 |
15V |
5,7A |
85W |
77% |
| 8067 |
24V |
4,2A |
100W |
78% |
| 8069 |
48V |
2,1A |
100W |
80% |
|
TECHNICAL
SPECIFICATIONS:
| AC
input voltage: |
110/220V |
| Mains
frequency: |
50/60Hz |
| Input
voltage range: |
±20% |
| DC
input voltage: |
240...360Vdc |
| Inrush
current: |
22A |
| Hold
time: |
>20ms |
| Output
voltage range: |
-0,
+20%Vonom |
| Load
regulation: |
<1,0% |
| Line
regulation: |
<0,2% |
| Ripple: |
<50mVpp |
| Noise: |
<100mVpp |
| Overload
protection: |
|
| - Light overloads: |
Constant
power |
| - Heavy overloads: |
Triggered |
| Dielectric
strength: |
|
| - Input - Output: |
3750Vrms/50Hz/1min |
| - Input - GND: |
1500Vrms/50Hz/1min |
| - Output - GND: |
500Vrms/50Hz/1min |
| Operating
temperature: |
|
| - Full load: |
0
÷ 50ºC |
| - Half load: |
0
÷ 70ºC |
| Storage
temperature: |
-25
÷ 80ºC |
| Format: |
3U
F1 10Te |
| Dimensions: |
100x160x40mm |
| Weight: |
460g |
| M.T.B.F.
(Hdbk MIL-217-E; GB; Ta=25°C): |
|
| Standards
conformity: |
EN50081-1 |
| - Emission: |
EN50082-1 |
| - Immunity: |
EN60950 |
| - Safety: |
150.000h |
|
PROTECTIONS:
Mains fuse.
Inrush current limited.
Against overloads and shortcircuits.
|
| STANDARD OPTIONS: |
 |
| Connections |
|
 |
Base: NP-9124
Base + cover: NP-9133 |
|
 |
Din
rail clip:
NP-9135 |
|
|
|
ORDERING INFORMATION EXAMPLE:
|
24V
/ 4,2A power supply with DIN connector: FC-100-8067/B
|
|
| A: |
Terminal blocks |
| B: |
Din connector 41.612 H15 |
| C: |
FASTON 6.35mm |
|
|
 |
Puede
obtener más información del producto (diagrama de bloques, conexionado, etc.. ),
descargando
la documentación en Portable Document Format (PDF) 184KB |
|