FBS-460
 
460W AC/DC POWER SUPPLY (SINGLE OUTPUT)
 
AC/DC power supply FBS-460
GENERAL FEATURES:

• Adjustable output voltage.
• No minimum load required.
• Selectable input line voltage.
• Fixed freq. pulse width modulation.
• Floating output voltage.
• Power-on indicator (led).
• Standard 19" rack mounting.
• Remote shutdown and sensing.

STANDARD MODELS CHART
Model V out I out

Max.
power

Typical efficiency
8143 12V 38,3A 460W 85%
8147 24V 19,2A 460W 87%
8149 48V 9,58A 460W 88%

TECHNICAL SPECIFICATIONS:

Selectable input voltage: 110/220V
Frequency range: 47...63Hz
Voltage range: +20...-15%
DC input voltage: 240...373Vdc
Inrush current: <32A
Hold time: >20ms
Output voltage range: ±15%Von
Load regulation: <0,3%Von
Line regulation: <0,3%Von
Protect. against overloads and shortcircuits: Current limiting
Protection against output overvoltages: 125...140%Von
Remote sensing (maximum Vdrop per cable): 0,3Vdc
Optocoupled remote shutdown: 5V...12Vdc
Ripple (mains + switching frequency): <50mVpp
Noise: <100mVpp
Dielectric strength:  
- Input - Output: >3000Vac
- Input - Ground: >1500Vac
- Output - Ground: >500Vac
Operating temperature:  
- Io = Iomax.: 0...50ºC
- Io = 1/2 Iomax.: 0...70ºC
Dimensions: 223x226x55mm (6U F2)
Approximate weight: 2,5Kg
Standard conformity:  
- E.M.C. (Emission): EN50081-1 EN61000-4-3
- E.M.C. (Immunity): EN50082-1 EN61000-4-2
- (Safety): EN60950
M.T.B.F. (HDBK MIL 217-E; GB, Ta = 25ºC): 150.000 h


PROTECTIONS:

• Inrush current limited.
• Against overvoltages and shortcircuits.
• Against output overvoltages: permanent.
• Metal box.