DC output Uninterruptible Power System |
|
|
|
|
| |
 |
|
 |
|
Twin output power supply (600W) |
|
|
 |
 |
|
|
Application: Power system for modular RF amplifier. |
|
| Features: |
|
Mains voltage:
Mains frequency range:
Power factor:
Out voltage Vdc1:
Out voltage Vdc2:
Max. power Vdc1:
Max. power Vdc2:
MTBF (MIL-HDBK-217-E): |
154...264Vac
180...360Vdc
47...63Hz
> 0.95
28...32V
24...28V
400W
200W
180.000 h |
|
|
| |
 |
| |
|
NP-0463 |
 |
|
|
Design year : 2000 |
 |
|
|
|
|
| Overload protection: linear / Shortcircuit protection: current limiting / Thermal protection: equipment’s shutdown / ON/OFF indicator: frontal connector for LED / DC OK indicator: frontal connector for LED and back TTL / Remote shutdown Vdc1: frontal connector and back connector / Safety according to norms: EN60950 / EMC norms: EN55022 EN50081-2 EN50082-2 / Others… |
|
|
 |
|
|
 |
|
|
| |
 |
|
 |
|
5 outputs power supply |
|
|
 |
 |
|
|
Application: Amplifier for satellite receivers. |
|
| Features: |
|
Input voltage:
Outputs:
Power:
Working Temperature:
Life expectancy:
Input/out. isolation:
Norms:
MTBF (MIL 217-E, GB, Ta=25ºC):
|
187...264Vca (50-60Hz)
30V 5V 12V 17V 24V
97.5W
0...50ºC
40.000 h @ 40ºC
1500Vac
EN60065 EN50081-1
EN50082-1 EN50083-2
550.000 h |
|
|
| |
 |
| |
|
NP-0437 |
 |
|
|
Design year : 1999 |
 |
|
|
|
|
|
|
 |
|
|
 |
|
|
| |
 |
|
 |
|
Non isolated step down converter for secondary regulated power supply |
|
|
 |
 |
|
|
Application: TV repeaters |
|
| Features: |
|
Input voltage:
Output:
Efficiency:
Working temperature:
MTBF (MIL 217-E, GB, Ta=25ºC):
|
27...60Vdc
24V 9A (220W)
>88%
0...70ºC
200.000 h |
|
|
| |
 |
| |
|
NP-0436 |
 |
|
|
Design year : 1999 |
 |
|
|
|
|
|
|
 |
|
|
 |
|
|
| |
|
| |